ESG and BUPRE are structured in three specialised divisions according to their activity:
Prefabricated
concrete.
Covers and prefabricated products

Gutters

Our ADIF gutters are manufactured and approved according to the Technical Specification of ADIF 03.305.001.4+M1 "PREFABRICATED CONCRETE CABLE DUCTS".

We have a chute handlerdesigned by our technical department, for the installation of the 400 and 600 single-channel models, with the possibility of adapting them to the 180 and 220 models.

They are laid parallel to the track and are fitted with 2 covers for each channel. After installation, they are flush.

TYPES OF ADIF TRUNKING

DESCRIPTIONWIDTHHEIGHTLENGTH
Gutter 180×130180130500
Gutter 180×1601801601000
Gutter 220×1952201951000
Gutter 400×2904002901000
Gutter 600×2906002901000
Biseno Gutter 450×2904502901000
Biseno Trunking 600×2906002901000
Biseno gutter 800×3408003401000


CHARACTERISTICS OF ADIF TRUNKING:

The prefabricated Adif trunking with embedded cover consists of:

The body of the gutterIt consists of a sill, which is the support base for the gutter, and two longitudinal walls parallel to each other and perpendicular to the sill.

The gutter coverThe cover, embedded in the body of the gutter, parallel to the sill, serves as a closure or cover for the gutter. The cover is divided lengthwise into two identical halves.

The faces or cross walls of the gutterThe openings in the centre of these cross-sections shall be provided with a tongue and groove joint to join the trunkings.

CAZ WATER COLLECTION CHUTE ADIF

They are placed in tunnels and viaducts, which require a large amount of water to be drained from their interiors. These The gutter covers are fitted with a slope and grooves in the gutter lids.These are used to remove surface water by channelling it away from the area. The lids are fitted with anchorages to the gutters in order to prevent them from moving or so that they can be dismantled for cleaning if necessary.

CHARACTERISTICS OF THE CAZ CHUTE

  • Evacuation slot with cover tilt 800 L x 60 W
  • Anchoring of the cover by means of hot-dip galvanised screws and washers UNE EN ISO - 1461 plus rubber washers.
  • Water evacuation channel 400 x 140

The CAZ gutters are installed in the Pajares tunnels in order to evacuate water from the platform.

The lighting pipe ducts with 2 or 4 holes are used for electrical trunking in tunnels using galvanised steel pipe.

Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.